Concrete Substation

The substations ENERGY are prefabricated post cast concrete, reinforced and vibrated conducted in a modern production unit and rational by our specialists of prefabrication and electrical equipment.

They enjoy the experience but also latest manufacturing techniques through the use of materials and electronic materials developed by manufacturers in recent years.
Transformer stations ENERGY meet the existing standards in force and allow the realization of all types of positions subscribers regardless of the material used for networks up to 24 KV.

HTA Transformer

Three-phase Transformer, insulated and cooled in oil, ONAN, 50 Hz, for an ambient temperature of 40°C maxi.
Installation inside (or outside on request), our transformers are sealed, with total filling.

BTA Transformer

solation transformers provide galvanic isolation and are used to protect against electric shock, to suppress electrical noise in sensitive devices, or to transfer power between two circuits which must not be connected.
An isolation transformer is a transformer used to transfer electrical power from a source of alternating current (AC) power to some equipment or device while isolating the powered device from the power source, usually for safety.

Cell Breaking in SF6

The HEXA 6 range consists of six functional units used up to 24kV for the realisation of table HTA for subscribers and industrial facilities.
It consists of modular cells with reduced pitch (375mm) equipped with equipment breaking in SF6.
Designed for indoor installations, the HEX 6 cells benefit from reduced dimensions, allowing to integrate them in cramped quarters or in prefabricated substations.

Cell Breaking in Air

The EUROBLOC 24 B cells are protected and prefabricated HT/BT, pitch 700 for switch cells, 1100 and 1300 mm for cells breaker.
These cells are isolated from the air and adapted to be installed inside building.
Green product without SF6 GAS. (Greenhouse gases)

Circuit Breaker Protection

A circuit breaker is a device cut-circuit, which can resist and break currents of an intensity at least equal to the rated current (In), and a protective device, which can automatically cut the current, which usually appear in the result of defects in the facilities.

Capacitor and Capacitor Banks

Fixed system
The reactive power supplied by the battery is constant whatever the variations of the power factor and the load of the receivers, and therefore the reactive energy consumption of the installation.

Automatic system
The reactive power supplied by the capacitor bank can be adjusted according to variations in the power factor and the load of the receivers, thus of the reactive energy consumption of the installation.

Electrical Links

– MTA Connection
– BTA Connection
– BT Connection
– Counting Link

Retention Tank

When storing hazardous substances or pollutants there may be a leak contaminates your warehouse or your sewer.
That is why there are holding tanks to be placed under your containers to prevent spills.